    | LMilW1560 is a 15.6" PCAP Full HD Panel PC with i3-6100U, IPS Wide Viewing Angle and 1600nits Backlight. | 
  
    |  | 
  
    | LMilW1560 - Cold start testing (1st time 2 hours) | 
  
    | 
 | 
  
    |  | 
  
    | LMilW1560 - Cold start testing (2nd time 4 hours) | 
  
    |  | 
  
    |  | 
  
    |  | 
  
    | LMilW1560 Cold Start Test Report | 
  
    |  | 
  
    | 1 Test Conditions | 
  
    |  | 
  
    | 1.1 Environmental Conditions Chamber: TERCHY_MHK-408LK
 | 
  
    |  | 
  
    | 1.2 Product General Descriptions | 
  
    | 15.6" PCAP Panel PC | 
  
    | 
 
   | Model No.: | LMilW1560 |  
   | OS | Windows 10 Enterprise 2016 L TBS |  
   | CPU | Intel Core i3-6100U CPU@ 2.30GHz |  
   | Memory | 4GB |  
   | Power Supply | EDACPOWER: EA10951F-120 OUTPUT: 12V |  | 
  
    |  | 
  
    | 1.3 Test Specifications | 
  
    | 1. First Stage: | 
  
    | First cool down to -40°C, let stand 2 hours and then turn it on by manual. Manual operation and running Burning Test, run for 1 minute and then shut down. | 
  
    | 
 
   | Step | Temperature | Duration | Remark |  
   | 0 | 25°C | 0H00M | Chamber-ON |  
   | 1 | -40°C | 2H00M | 25°C cool down to -40°C |  
   | 2 | -40°C | 2H00M |  |  | 
  
    |  | 
  
    | 2. Second Stage | 
  
    | First cool down to -40°C, let stand 4 hours and then turn it on by manual. Manual operation and running Burning Test, run for 1 minute and then shut down. | 
  
    | 
 
   | Step | Temperature | Duration | Remark |  
   | 0 | 25°C | 0H00M | Chamber-ON |  
   | 1 | -40°C | 2H00M | 25°C cool down to -40°C |  
   | 2 | -40°C | 2H00M |  |  | 
  
    |  | 
  
    | 2 Test Result | 
  
    | First stage test results: PASS Second stage test results: PASS
 |