Click "OPTION" tab to customize or call 1-888-483-2418 for detail
General Specifications |
|
Description |
DC power input for Cyberview 12V, 24V, 48V DC input option |
Input Voltage |
48V input with 36 - 75V, 1220mA |
24V input with 18 - 36V, 2450mA |
12V input with 9 - 18V, 4950mA |
|
Output Voltage |
12 VDC, 4.16A |
Efficiency |
85% (48V input) |
85% (24V input) |
84% (12V input) |
|
Isolation Voltage |
1500 VDC min. |
Isolation Resistance |
10,000,000 ohm min. |
Switching Frequency |
300KHz, Typ. (48V input) |
400KHz, Typ. (24V/ 12V input) |
|
Circuit Protection |
Continuous Short Circuit Protection |
Input Specification |
|
Input Voltage Range |
48V input with 36-75 V, Max. 1220mA
24V input with 18-36 V, MAx. 2450mA
12V input with 9-18 V, Max. 4950mA |
Undervoltage Lockout |
Power Up/Down= 34V / 32.5V (48V input)
Power Up/Down= 17V / 16V (24V inputl)
Power Up/Down= 8.8V / 8V (12 input) |
Input Filter |
PI Type |
Output Specifications |
|
Voltage Accuracy |
+/- 1% max. |
Transient Response |
25% Step Load Change < 500u sec. |
External Trim Adj. Rnage |
+/- 10% |
Ripple & Noise (20MHz BW.) |
24V Input: 100mV RMS., max. 240mV pk-pk, max.
12V Input: 30mV RMS., max. 100mV pk-pk, max. |
Temperature coefficient |
+/- 0.03% / Degree Celsius |
Short Circuit Protection |
Continuous |
Line Regulation |
+/- 0.2% max. |
Load Regulation |
+/- 0.2% max. |
Over Voltage Protection Trip Range |
115-140% Vo nom |
Current Limit |
110% ~ 150% Nominal Output |
|