Metered CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meter, 3 Phase D input w/L1530 connector & cord, 10' (Model: C-24VD-L30A)

Metered CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meter, 3 Phase D input w/L1530 connector & cord, 10' (Model: C-24VD-L30A)

Metered CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meter, 3 Phase D input w/L1530 connector & cord, 10' (Model: C-24VD-L30A)

C-24VD-L30A
  • Overview
Mid-Density Metered Power Distribution
Increasing power demands and density in the equipment cabinet
requires new functionality from your cabinet PDU. The Sentry CDU
product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU
with local LED input current monitoring, allowing network engineers to
utilize the CDU’s True RMS Power Monitor to precisely measure the
current (in amps) that network devices are drawing on the power circuit.
As new servers and devices are added to the power drop, immediately
observe its impact on the cumulative current draw. This allows the
engineer to safely load each circuit to its maximum allowable load
capacity without the danger of overloading the power circuit.

Key Features:
> Input Current Monitor:
Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display.
> Power Distribution:
208V, three phase power with 20 or 30 Amp power input feed options.
> Mid-Density:
Single power input feed; 24 outlets per enclosure; QTY (18) C13 outlets and qty (6) C19 outlets

Additional Benefits:
Branch Circuit Protection
The Sentry CDU Family meets the new UL 60950-1
requirement for branch circuit protection.
Attention!
The Sentry CDU products meet the above criteria by
providing overcurrent protection with UL-listed Bussman SC fuses for
each branch circuit.
Input Current Monitoring
The CDU’s exclusive True RMS current monitoring is critical
to preventing overloads in high-density computing
environments. LED digital displays on the CDU enclosure
report the input current of each phase or branch circuit
Outlet Diversity
This Metered C-24V CDU is equipped with a combination
of qty (18) IEC 60320/C13 and qty (6) 60320/C19 outlets.


CDU Technical Specifications :
Model
Available Input
Voltages
Amperage
Available Input Cord
Outlets
Dimensions (L x W x D)
C-24V2-L20A
208-240V
50/60Hz
20A
NEMA L6-20P Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
208-240V
50/60Hz
30A
NEMA L6-30P Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
C-24VD-L20A
3-Phase, 208V, Delta
50/60Hz
20A
NEMA L15-20P Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
3-Phase, 208V, Delta
50/60Hz
30A
NEMA L15-30P Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
C-24VY-L20A
3-Phase, 208V, Wye
50/60Hz
20A
NEMA L21-20P Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
3-Phase, 208V, Wye
50/60Hz
30A
NEMA L21-30P Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
C-24VY-P30A
3-Phase, 240V, Wye
50/60Hz
30A
IEC 60309 Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
C-24VE-P16A*
230V
50/60Hz
16A
IEC 60309 Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
C-24VE-P32A*
230V
50/60Hz
32A
IEC 60309 Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
C-24V4-P16A*
3-Phase, 400V
50/60Hz
16A
IEC 60309 Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”
C-24V4-P32A*
3-Phase, 400V
50/60Hz
32A
IEC 60309 Cordset
(18) IEC/C13
(6) IEC/C19
63.5” x 1.75” x 2.25”


Additional Specifications :
Power Cord Options
> PTCORD-1
IEC 60320/C19 - NEMA L6-20P ,10’
> PTCORD-2
IEC 60320/C19 - Schuko 10’
> PTCORD-3
IEC 60320/C19 - IEC 60309 (BS4343,CEE17)
16/20A Blue (UK Commando) 10’
> PTCORD-4
IEC 60320/C19 - BS1363 13A (UK) 10’
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector